Aquasolve 500LPH Reverse Osmosis (RO) System
₵23,700.00
The Aquasolve 500LPH RO System is a high-capacity water purification unit designed to deliver up to 500 liters per hour of pure, safe, and great-tasting water. Ideal for commercial and industrial applications, this system effectively removes contaminants, dissolved solids, and impurities to provide clean water for various uses.
Technical Specifications
General Information:
- Model: AQ-RO-500LPH
- Production Capacity: 500 Liters Per Hour
- Recovery Rate: Up to 50%
- Rejection Rate: Up to 98% of total dissolved solids (TDS)
- Operation Mode: Automatic with manual override
Components:
- RO Membrane Housings:
- Quantity: 2 units
- Material: FRP (Fiber Reinforced Plastic) or Stainless Steel
- Size: Compatible with 4″ × 40″ RO membranes
- Pressure Rating: Up to 300 psi (21 bar)
- RO Membranes:
- Quantity: 2 units
- Type: Thin Film Composite (TFC)
- Size: 4″ × 40″
- Maximum Operating Pressure: 300 psi (21 bar)
- Operating pH Range: 3 – 11
- Maximum Feed Water TDS: 2000 ppm
- High-Pressure Pump:
- Type: Multi-stage centrifugal pressure pump
- Material: Stainless Steel
- Motor Power: Approximately 2.2 kW (3 HP)
- Voltage: 220V/50Hz or 380V/50Hz (customizable)
- Operating Pressure: 150 – 200 psi (10 – 14 bar)
- 12″ × 65″ Multimedia Filter System:
- Tank Size: 12″ diameter × 65″ height
- Tank Material: FRP (Fiber Reinforced Plastic)
- Filter Media: Layers of gravel, silica sand, garnet, and anthracite
- Function: Removes sediment, turbidity, suspended solids, and reduces chlorine
- Flow Rate: Suitable for pre-treatment of 500 LPH RO system
Control & Instrumentation:
- Control Panel: Includes on/off switches, indicator lights, and system status display
- Pressure Gauges: Monitoring feed water, pump pressure, and membrane pressure
- Flow Meters: Permeate and concentrate flow rates
- TDS Meter: Online monitoring of product water quality
- Low & High-Pressure Switches: Protects the pump and system from abnormal pressure conditions
Connections:
- Feed Water Inlet: 1″ BSP/NPT
- Permeate (Product Water) Outlet: 1/2″ BSP/NPT
- Concentrate (Reject Water) Outlet: 1/2″ BSP/NPT
- Drain Connection: 1/2″ BSP/NPT
Physical Dimensions:
- Overall Dimensions (L × W × H): Approximately 1200 mm × 700 mm × 1600 mm
- Weight: Approximately 150 kg (depending on final configuration)
Operating Conditions:
- Feed Water Temperature: 5°C – 40°C
- Feed Water pH Range: 3 – 11
- Maximum Feed Water SDI (Silt Density Index): < 5
- Electrical Requirements: 220V/50Hz Single Phase or 380V/50Hz Three Phase
Features & Benefits
- High-Capacity Production: Delivers up to 500 litres per hour, suitable for higher-demand applications.
- Quality Components: constructed with durable materials like stainless steel and FRP for longevity and corrosion resistance.
- Efficient Filtration: Dual TFC RO membranes provide up to 98% TDS rejection for superior water purity.
- Enhanced Pre-Treatment: The 12″ × 65″ multimedia filter effectively removes particulates and chlorine, protecting the RO membranes and extending their lifespan.
- Energy-Efficient Pump: High-pressure pump designed for optimal performance with low energy consumption.
- User-Friendly Operation: intuitive control panel and comprehensive instrumentation for easy monitoring and control.
- Compact Design: Optimized footprint for ease of installation in limited spaces.
Applications
- Food & Beverage Industry
- Pharmaceutical Production
- Laboratories and Research Centers
- Hotels and Restaurants
- Bottled Water Plants
- Industrial Processes Requiring High-Purity Water
Scope of Supply
- Main RO Unit: Pre-assembled on a powder-coated steel frame
- RO Membrane Housings: 2 units with installed RO membranes
- High-Pressure Pump: Installed and connected
- 12″ × 65″ Multimedia Filter: Complete with media and control valve
- Control Panel: Wired and tested
- Instrumentation: Pressure gauges, flow meters, TDS meter
- Piping & Fittings: All necessary interconnections within the system
Optional Accessories
- UV Sterilizer: For additional microbial control
- Activated Carbon Filter: For removal of organic compounds and residual chlorine
- Water Softener: For hard water applications
- Antiscalant Dosing System: To prevent membrane scaling
- Clean-In-Place (CIP) System: For membrane cleaning and maintenance
- Storage Tanks: For permeate and feed water
Installation & Maintenance
- Installation: This should be performed by qualified technicians. Detailed installation manual provided.
- Maintenance: Regular checks are recommended for optimal performance. Membrane and filter media replacement intervals depend on feed water quality and usage.
Warranty & Support
- Warranty: 1-year limited warranty on manufacturing defects
- Technical Support: Available via phone or email during business hours
- Spare Parts: Readily available upon request
- Service Contracts: Optional extended service agreements
Ordering Information
- Product Code: AQ-RO-500LPH
- Availability: Typically in stock; please contact for current lead times
Note: Specifications are subject to change without prior notice due to continuous product improvement.
Reviews
There are no reviews yet.