16W UV Water Sterilizer

1,000.00

The 16W UV Water Sterilizer is a compact and efficient ultraviolet disinfection system designed for low-flow applications. It effectively removes bacteria, viruses, and other harmful microorganisms, ensuring safe and clean water for residential and point-of-use systems.

Category: ,
Tags:

Technical Specifications

General Specifications

  • UV Lamp Power: 16 Watts
  • UV Wavelength: 254 nm (Germicidal Range)
  • Disinfection Flow Rate:
    • Up to 2 GPM (7.6 LPM) for 99.9% disinfection at 30 mJ/cm².
  • Lamp Life: 9,000 hours (approx. 1 year of continuous use)
  • Material: 304 Stainless Steel Housing
  • Inlet/Outlet Connection Size: ½-inch BSP/NPT Threaded Ports
  • Power Supply:
    • Voltage: 110–240V AC, 50/60 Hz
    • Power Consumption: 16W

Performance Parameters

Parameter Value
Maximum Operating Pressure 6 bar (87 psi)
Operating Temperature 2–40°C (36–104°F)
Minimum UV Transmittance 75% (recommended)

Physical Dimensions

  • Length: 375 mm (14.8 inches)
  • Diameter: 63.5 mm (2.5 inches)
  • Weight: ~1.8 kg (4 lbs)

Applications

  • Point-of-Use Water Treatment: Ensures safe drinking water at a single tap or appliance.
  • Residential Use: Ideal for small households or individual faucets.
  • Aquarium and Pond Water Treatment: Protects aquatic life from harmful microorganisms.
  • RO System Post-Treatment: Provides an additional sterilization layer for RO-purified water.
  • Light Commercial Applications: For small-scale water sterilization needs.

Features and Benefits

  • Compact Design: Perfect for tight spaces and small-scale applications.
  • Chemical-Free Disinfection: Kills harmful pathogens without affecting water quality or taste.
  • Durable Stainless Steel Housing: Corrosion-resistant and robust for long-term use.
  • Low Energy Consumption: Efficient operation with minimal power requirements.
  • Ease of Maintenance: Quick and easy lamp and quartz sleeve replacement.

Usage Guidelines

Installation

  1. Mount the sterilizer in a horizontal position for proper flow and exposure.
  2. Pre-filter the water with a 5-micron filter to remove sediments that may interfere with UV transmission.
  3. Connect to a compatible power supply using the included ballast.

Operation

  • Allow the UV lamp to warm up for 2–3 minutes to reach optimal performance.
  • Ensure water flow does not exceed 2 GPM for effective disinfection.

Maintenance

  • Replace the UV lamp annually (9,000-hour lifespan).
  • Clean the quartz sleeve periodically to maintain UV efficiency.

Packaging and Storage

  • Packaging:
    • Each unit is individually boxed with foam padding for safety.
    • Includes UV lamp, quartz sleeve, ballast, and mounting hardware.
  • Storage Instructions:
    • Store in a cool, dry place away from direct sunlight and extreme temperatures.

Safety and Compliance

  • Certifications: CE and RoHS compliant.
  • Safety Notes:
    • Avoid direct exposure to UV light; it can cause skin and eye damage.
    • Disconnect power before performing any maintenance or service.

Warranty

  • Coverage: 12-month limited warranty on system components and UV lamp.