4040 Runmo Membrane

2,050.00

The Runmo 4040 BW (Brackish Water) Reverse Osmosis Membrane is a high-performance filtration element designed for the efficient removal of dissolved salts, organic contaminants, and other impurities from brackish water sources. Engineered for long life and exceptional performance, this membrane is ideal for use in industrial, commercial, and municipal water treatment systems.

Technical Specifications

General Specifications

  • Model: 4040 BW
  • Membrane Type: Thin Film Composite (TFC) Polyamide
  • Active Surface Area: ~7.9 m² (85 ft²)
  • Configuration: Spiral Wound
  • Element Dimensions:
    • Diameter: 4.0 inches (102 mm)
    • Length: 40.0 inches (1,016 mm)
  • Weight: ~3.6 kg (8 lbs)

Performance Parameters

Property Value
Permeate Flow Rate ~2,400 GPD (9,085 L/day)
Salt Rejection Rate ≥ 99.5%
Operating Pressure 150 psi (10 bar)
Maximum Operating Pressure 600 psi (41 bar)
Recovery Rate Up to 15% per element
pH Range (Continuous): 3 – 10
pH Range (Cleaning): 2 – 11
Chlorine Tolerance 0 ppm
Max Operating Temperature 45°C (113°F)

Applications

  • Brackish Water Desalination: Removal of dissolved salts and contaminants from brackish water sources.
  • Industrial Water Treatment: Producing high-purity water for manufacturing and processing.
  • Commercial Use: Hotels, hospitals, and beverage industries requiring purified water.
  • Pre-treatment for High-Pressure Boilers: Removes scale-forming minerals and silica.
  • Municipal Water Systems: Supplies safe and clean water to communities.

Features and Benefits

  • High Salt Rejection: Removes up to 99.5% of dissolved salts, ensuring clean, purified water.
  • Efficient Water Flow: Provides consistent performance with high permeate output.
  • Durable Construction: Withstands high operating pressures and challenging water conditions.
  • Energy-Efficient: Optimized for low energy consumption without sacrificing performance.
  • Easy Installation: Standard 4040 design compatible with industry-standard pressure vessels.

Usage Guidelines

Installation and Operation

  • Ensure proper pre-treatment to protect the membrane from fouling, scaling, and physical damage.
  • Operate within specified pressure and pH ranges for optimal performance.
  • Monitor system parameters such as pressure drop, permeate flow, and salt rejection.

Cleaning and Maintenance

  • Perform chemical cleaning when normalized permeate flow decreases by 10%, or salt rejection decreases by 5%.
  • Use compatible cleaning chemicals with a pH range of 2–11.

Packaging and Storage

  • Packaging:
    • Individually wrapped in a protective polyethylene bag with desiccant inside a cardboard box.
  • Storage Instructions:
    • Store in a cool, dry place away from direct sunlight.
    • Keep hydrated; do not allow the membrane to dry out during storage or after first use.

Safety and Compliance

  • Certifications: ISO 9001, NSF/ANSI Standard 58 compliant for potable water applications.
  • Handling Precautions:
    • Handle carefully to avoid physical damage to the membrane.
    • Use personal protective equipment during installation and cleaning procedures.

Warranty

  • Coverage: 12-month limited warranty against manufacturing defects, provided operating conditions are met.