Your cart is currently empty!
40W UV Water Sterilizer
₵2,500.00
Technical Specifications General Specifications UV Lamp Power: 40 Watts UV Wavelength: 254 nm (Germicidal Range) Disinfection Flow Rate: Up to 10 GPM (37.8 LPM) for 99.9% disinfection at 30 mJ/cm². Lamp Life: 9,000 hours (approx. 1 year of continuous use) Material: 304 Stainless Steel Housing Inlet/Outlet Connection Size: ¾-inch BSP/NPT Threaded Ports Power Supply: Voltage:…
Technical Specifications
General Specifications
- UV Lamp Power: 40 Watts
- UV Wavelength: 254 nm (Germicidal Range)
- Disinfection Flow Rate:
- Up to 10 GPM (37.8 LPM) for 99.9% disinfection at 30 mJ/cm².
- Lamp Life: 9,000 hours (approx. 1 year of continuous use)
- Material: 304 Stainless Steel Housing
- Inlet/Outlet Connection Size: ¾-inch BSP/NPT Threaded Ports
- Power Supply:
- Voltage: 240V AC, 50/60 Hz
- Power Consumption: 40W
Performance Parameters
Parameter | Value |
---|---|
Maximum Operating Pressure | 6 bar (87 psi) |
Operating Temperature | 2–40°C (36–104°F) |
Minimum UV Transmittance | 75% (recommended) |
Physical Dimensions
- Length: 890 mm (35 inches)
- Diameter: 63.5 mm (2.5 inches)
- Weight: ~3.5 kg (7.7 lbs)
Applications
- Residential Use: Provides safe drinking water for medium to large households.
- Commercial Applications: Ideal for cafes, small hotels, and schools.
- Aquaculture: Ensures pathogen-free water for fish tanks and ponds.
- Industrial Water Systems: Sterilizes water in light industrial processes.
- Pre-Treatment for RO Systems: Provides an added layer of protection for RO-treated water.
Features and Benefits
- High-Flow Capacity: Capable of treating up to 10 GPM, meeting medium-scale water demands.
- Chemical-Free Disinfection: Kills harmful microorganisms without altering water properties.
- Durable Stainless Steel Housing: Corrosion-resistant and built for long-term use.
- Energy Efficient: Optimized for low power consumption with high sterilization efficiency.
- Easy Installation and Maintenance: Compact design and simple lamp and sleeve replacement.
- Enhanced Safety: UV exposure ensures disinfection without the use of harmful chemicals.
Usage Guidelines
Installation
- Install the unit horizontally for optimal performance.
- Pre-filter water to remove sediments that may reduce UV transmission (5-micron filter recommended).
- Ensure proper electrical grounding and connect the sterilizer to the power source using the included ballast.
Operation
- Allow the UV lamp to warm up for 2–3 minutes before use.
- Monitor the flow rate to ensure proper exposure and disinfection.
Maintenance
- Replace the UV lamp every 9,000 hours (approximately 1 year).
- Clean the quartz sleeve periodically to maintain optimal UV transmission.
Packaging and Storage
- Packaging:
- Individually packed in a protective box with foam padding.
- Includes UV lamp, quartz sleeve, ballast, and mounting brackets.
- Storage Instructions:
- Store in a cool, dry environment away from direct sunlight.
Safety and Compliance
- Certifications: CE and RoHS compliant.
- Safety Notes:
- Avoid direct exposure to UV light; it can harm skin and eyes.
- Ensure the system is powered off during servicing or maintenance.
Warranty
- Coverage: 12-month limited warranty on system components and UV lamp.